logo
Send Message
products

ATOS RZGO-TERS-PS-033 100 54 Hydraulic Proportional Valve Stainless Steel New

Basic Information
Place of Origin: Italy
Brand Name: ATOS
Certification: cc
Model Number: RZGO-TERS-PS-033 100 54
Minimum Order Quantity: 1
Price: RMB/100-10000/PC
Packaging Details: wooden case/carton
Delivery Time: 3 work days
Payment Terms: T/T
Supply Ability: 10PCS/days
Detail Information
Number Of Wire: 3 Quality: A+ With Waranty
Max Temperature: 80°C Material: Stainless Steel
Temperature Of Media: 20 Maximum Flow Rate: 400l/min
Valve Size: 1 Inch Power: Solenoid
Highlight:

Stainless Steel Hydraulic Proportional Valve

,

ATOS RZGO-TERS-PS-033 Hydraulic Proportional Valve

,

Hydraulic Proportional Valve


Product Description

Product Description:

 

Advantages and features of ATOS proportional pressure reducing valve


Precise control:
It can realize stepless adjustment of pressure and speed, avoiding the impact phenomenon when the traditional switch-type gas valve is switched.


With electronic closed-loop feedback, it can accurately adjust the output pressure according to the input signal.


Remote and program control:
Support remote control and program control, easy to integrate into the automation system.


Can be connected with digital drivers, configured and controlled by software.


System simplification:
Compared with intermittent control, the system is simpler and the number of components is greatly reduced.


High reliability:
Adopting advanced electro-hydraulic technology, it has high precision, high response and high reliability.


Insensitive to impurities and high reliability.


Energy saving and environmental protection:
Low power consumption, low heat generation and low noise.


No fire, no pollution to the environment, and little impact by temperature changes.


Flexibility and compatibility:
Can be used with external drivers or necessary electronic components.


A variety of models and specifications are available for different application scenarios.


Precautions for the use of ATOS proportional pressure reducing valve


Pre-installation preparation:
Read the instruction manual of the equipment carefully to understand the basic parameters and operating requirements of the equipment.


Ensure that the power supply voltage and frequency meet the rated value of the equipment.


Check that all pipe connections are secure and there are no leaks.


Ensure that the filter is clean and not clogged.


Startup and commissioning:
Close the oil inlet valve before starting to prevent damage to the equipment due to sudden loading.


Slowly open the oil inlet valve to allow the system to gradually fill with oil, while observing the pressure gauge reading to ensure that the pressure rises steadily.


According to system requirements, gradually adjust the setting value of the proportional pressure reducing valve to ensure that the pressure is stable within the required range.


Operation monitoring:
Regularly measure the operating temperature of the proportional pressure reducing valve to ensure that it is within the normal operating temperature range.


Regularly check the temperature and insulation performance of the solenoid coil to prevent overheating or short circuit.


Regularly check the wear of the seals and replace new seals if necessary.


Shutdown and maintenance:
When shutting down, slowly close the oil inlet valve to stop supplying oil to the system.


Disconnect the power supply and release the pressure in the system.


Clean the valve body and internal parts regularly to remove sludge and impurities.


Lubricate moving parts regularly to reduce wear.


Pressure reduction ratio control:
The pressure reduction ratio P1:P2 should not be too large, and should generally be controlled within 5:1, otherwise cavitation is likely to occur and damage the valve parts.


Avoid blockage:
For pressure reducing valves with small holes, be careful not to block the small holes, otherwise it will affect the normal operation of the pressure reducing valve.


Installation position:
To reduce the complexity of operation, it is recommended to install it on a horizontal pipeline.


Through the above precautions, the efficient operation and long service life of the ATOS proportional pressure reducing valve can be ensured.

 

Valve Type Proportional Valve
Voltage 24 VDC
Response Time 10 ms
Model RZMO-A-010 100 20
Maximum Pressure 31.5mpa
Assernbly Position Any position
Weight 0.5 kg
Number Of Wire 3
Quality A+ With Waranty
Max Temperature 80°C

 

ATOS RZGO-TERS-PS-033 100 54 Hydraulic Proportional Valve Stainless Steel New 0

 

FAQ

Q1: Wonder if you accept small orders?
A1: Do not worry. Feel free to contact us .in order to get more orders and give our clients more convener ,we accept small order.

Q2: Can you send products to my country?
A2: Sure, we can. If you do not have your own ship forwarder, we can help you.

Q3: What's your payment terms ?
A3: By T/T,LC AT SIGHT,100% full payment.

Q4: How long is your production lead time?
A4:It depends on product and order qty. Normally, it takes us 15 days for an order with MOQ qty.

Q5: When can I get the quotation ?
A5: We usually quote you within 24 hours after we get your inquiry. If you are very urgent to get the quotation.Please call us or tell us in your mail, so that we could regard your inquiry priority.

Contact Details
Rachel

Phone Number : +8618169083495

WhatsApp : +15396656017